Skip to search boxSkip to navigationSkip to main content

Stretching at the ankle joint: viscoelastic responses to holds and continuous passive motion

  • ,
  • Peter J. McNair
    ,
  • Erik Dombroski
    ,
  • Stephen N. Stanley
Research Output: Contribution to journal Article Peer-review

Abstract

PURPOSE: To compare the effect of static holds and continuous passive motion on stiffness and force relaxation of the soft tissue structures resisting ankle joint dorsiflexion. METHODS: This study used a randomized repeated measures trial design. Twenty-four asymptomatic subjects (15 males and 8 females) with a mean age of 26 yr participated. A Kin-Com dynamometer was used to measure the stiffness and force relaxation response of tissues about the ankle joint in response to a plantar flexor stretch. A comparison was made of the response for a 1 x 60-s hold, 2 x 30-s holds, 4 x 15-s holds, and continuous passive motion for 60 s. All subjects undertook all conditions. The main outcome measures were 1) stiffness at the ankle joint as it moved to 80% of the maximum range of dorsiflexion, and 2) the decrease in force at 80% of the maximum range of motion of the ankle joint. RESULTS: Stiffness was decreased significantly (P < 0.05) for the continuous passive motion condition only. The mean magnitude of the decrease in stiffness was 16%. Across hold times, force decreased significantly (P < 0.05). Bonferonni contrasts indicated that there was a significant difference (P < 0.05) between the continuous passive motion condition and all other hold conditions. There were no significant differences (P > 0.05) between the 4 x 15-s, 2 x 30-s, and 1 x 60-s holds. The magnitude of the decline in force was 10.5%, 21.5%, 21.7%, and 19% for the 0-, 15-, 30-, and 60-s holds, respectively. The greatest decreases in tension were achieved in the first 20 s of a hold. CONCLUSION: If decreasing stiffness is a key aim of a stretching program, the findings indicate that continuous motion is more effective than holds. In contrast, if relaxation of peak tension is the main aim, then holds are most effective.

Publication Information

Output type

Research Output: Contribution to journal Article Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 354-358

Journal (Volume, Issue Number)

Medicine and Science in Sports and Exercise (Volume 33, Issue 3)

Publication milestones

  • Published - 31/03/2001

Publication status

Published - 31/03/2001

ISSN

0195-9131

External Publication IDs

  • handle.net: 10547/623454
  • Scopus: 0035099360

Publication metrics