Abstract
This study deals with the deduction of parameters of Micro-Perforated Panel (MPP) systems from impedance tube data. It is shown that there is an ambiguity problem that exists between the MPP thickness and its open area ratio. This problem makes it difficult to invert the reflection coefficient data fitting and therefore to deduct the MPP parameters. A technique is proposed to reduce this ambiguity by using an equation that links the hole diameter to the open area ratio. Reflection coefficient data obtained for two specimens with different characteristics is employed for searching the MPP parameters using a simulated annealing algorithm. The results obtained demonstrate the effectiveness of this technique.
| Original language | English |
|---|---|
| Pages (from-to) | 2279-2288 |
| Journal | Journal of the Acoustical Society of America |
| Volume | 143 |
| Issue number | 4 |
| DOIs | |
| Publication status | Published - 20 Apr 2018 |
Keywords
- Micro-Perforated Panel (MPP) systems
Fingerprint
Dive into the research topics of 'On the simultaneous inversion of micro-perforated panels' parameters: application to single and double air-cavity backed systems'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver